# Le Louvre Systems™ Suspended Continuous

> AI-readable product knowledge document for the Beta-Calco product **Le Louvre Systems™ Suspended Continuous** (product id 569). Generated 2026-09-19T08:51:38+00:00 from the live product data. Every section names the page or file where a visitor can see the same information. Machine-readable form: https://betacalco.com/cb-api/bcproductknowledge/json?productId=569

## At a glance

| Field | Value |
|---|---|
| Product id | 569 |
| Title | Le Louvre Systems™ |
| Subtitle | Suspended Continuous |
| Listed under | Linear |
| Product family | Le Louvre (Linear) — https://betacalco.com/component/configbox/?view=bcproductsbyfamily&family_id=83 |
| Designer | Serge Cornellisen — https://betacalco.com/designers/serge-cornellisen |
| Status | active — declare compliant, configurable |
| Launched | 2023-01-12 00:00:00 |
| Lumen range | 100 – 2800 |
| Offered to customer groups | US Agent, US Specifier, Canada Agent, Canada Specifier, UK Agent, UK Specifier, Export USD Specifier, Export USD Agent, EU Agent, EU Specifier, UK Buysell Agent |

### Quick profile

Distilled from the sections of this document for matching a visitor's needs. Lists are de-duplicated and capped; the configurator section has the full detail.

- Facets — Category: Linear · Aperture (inches): 2.1 - 3.0 · Aperture (millimetres): 51 - 75 · Mounting: Suspended · Types: Linear Profiles · Features: Indirect, Asymmetric, Batwing, BIOS, Color Accent, Dali, Declare, Louvered, PoE, Tunable White, Low UGR, Wood Finish · Shapes: Linear
- Light — 100–2800 lm · Lm/ft (Direct): 100 lm/ft, 200 lm/ft, 300 lm/ft, 400 lm/ft, 500 lm/ft, 600 lm/ft, 700 lm/ft, 800 lm/ft, 1000 lm/ft, 1200 lm/ft · Lm/ft (Indirect): 250 lm/ft, 500 lm/ft, 750 lm/ft, 1000 lm/ft, 1200 lm/ft, 1600 lm/ft · direction: 2ft middle section Direct, 2ft middle section with power cord Direct, 2ft section with end cap Direct, 2ft section with end cap and power cord Direct, 4ft middle section Direct, 4ft middle section with power cord Direct, 4ft section with end cap Direct, 4ft section with end cap and power cord Direct, 4ft middle section Direct/Indirect, 4ft middle section with power cord Direct/Indirect, 4ft section with end cap Direct/Indirect, 4ft section with end cap and power cord Direct/Indirect, 6ft middle section Direct, 6ft middle section with power cord Direct, 6ft section with end cap Direct, 6ft section with end cap and power cord Direct, 6ft middle section Direct/Indirect, 6ft middle section with power cord Direct/Indirect, 6ft section with end cap Direct/Indirect, 6ft section with end cap and power cord Direct/Indirect, 8ft middle section Direct, 8ft middle section with power cord Direct, 8ft section with end cap Direct, 8ft section with end cap and power cord Direct, 8ft middle section Direct/Indirect, 8ft middle section with power cord Direct/Indirect, 8ft section with end cap Direct/Indirect, 8ft section with end cap and power cord Direct/Indirect, 10ft middle section Direct, 10ft middle section with power cord Direct, 10ft section with end cap Direct, 10ft section with end cap and power cord Direct, 10ft middle section Direct/Indirect, 10ft middle section with power cord Direct/Indirect, 10ft section with end cap Direct/Indirect, 10ft section with end cap and power cord Direct/Indirect, 12ft middle section Direct, 12ft middle section with power cord Direct, 12ft section with end cap Direct, 12ft section with end cap and power cord Direct, 12ft middle section Direct/Indirect, 12ft middle section with power cord Direct/Indirect, 12ft section with end cap Direct/Indirect, 12ft section with end cap and power cord Direct/Indirect, Corner with no end caps Direct, Corner middle with power cord Direct, Corner with Left end cap Direct, Corner with Right end cap Direct, Corner with Left end cap and power cord Direct, Corner with Right end cap and power cord Direct, Corner with no end caps Direct/Indirect, Corner middle with power cord Direct/Indirect, Corner with Left end cap Direct/Indirect, Corner with Right end cap Direct/Indirect, Corner with Left end cap and power cord Direct/Indirect, Corner with Right end cap and power cord Direct/Indirect · CCT 3000K, 3500K, 4000K · CRI 80, CRI 90
- Build — finishes: White - Textured, Black Metallic - Textured, Silver Metallic - Textured, Gold Metallic - Textured, Wood grain - Light Cherry ¹, Wood grain - Dark Walnut ¹, Wood grain - White Oak ¹, Midnight Blue Metallic - Textured, Copper Metallic, Charcoal Metallic - Textured, Bronze Metallic - Textured, Champagne Metallic, Red Metallic - Textured, White · mounting: Suspended Direct, Suspended Direct/Indirect
- Options — voltage 120/277V/240V/347V · dimming: 0-10V Dimming 1.0%, 0-10V Dimming 0.1% ¹, DALI Dimming 0.1% ¹, DALI Dimming 1.0% ¹, DSI/switchDim ², PoE ³ · emergency: Emergency system - Integral ¹, Emergency generator circuit ¹ · optics: Louver: Frosted; Louver: Black; Louver: Satin Chrome; Louver: Satin Gold; Louver: Satin Champagne; Direct Lens: Asymmetric ¹; Direct Lens: Comfort; Indirect Lens: Batwing; Indirect Lens: Asymmetric diffuser ¹; Indirect Lens: Extra Wide Batwing
- Ratings & notes — ETL, CE, Grounding, Damp Location (Indoor Use), Mounting Suited On Flammable Surfaces, IP 20 · applications: Bios, Declare, PoE · designer Serge Cornellisen

### Where to find it

- Configurator page: https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator
  - Sections: gallery https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#gallery · downloads https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#downloads · tech specs https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#specs · configurator https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#configurator
- Full specification sheet (PDF): imperial https://betacalco.com/specsheets/lelouvre-systems-pd/full/imperial · metric https://betacalco.com/specsheets/lelouvre-systems-pd/full/metric
- Short specification sheet (PDF): imperial https://betacalco.com/specsheets/lelouvre-systems-pd/short/imperial · metric https://betacalco.com/specsheets/lelouvre-systems-pd/short/metric
- Product family page: https://betacalco.com/component/configbox/?view=bcproductsbyfamily&family_id=83
- Resources & downloads page: https://betacalco.com/resources
- Products page: https://betacalco.com/component/configbox/productlisting?listing_id=0

## Description

_Source: Configurator page (intro) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#top-part_

The striking new concept in louver technology is disrupting the linear lighting category, and taking glare control to new heights. The LE LOUVRE's award-winning design with diagonal cross-hatched construction of the louver in a soft concave shape provides not just visual comfort but a touch of panache unseen in traditional linear lighting. Louvers are available in white for higher performance, black for the highest glare control, and rich satinized finishes - chrome, gold, champagne, for elegant interior designs. Build a continuous lighting plan with the new LE LOUVRE SYSTEMS option.

Product Overview:

The striking new concept in louver technology is disrupting the linear lighting category, and taking glare control to new heights. Our award-winning design with diagonal cross-hatched construction of the louver in a soft concave shape provides not just visual comfort but a touch of panache unseen in traditional linear lighting. Louvers are available in white for higher performance, black for the highest glare control, and rich satinized finishes - chrome, gold, champagne, for elegant interior designs.

Body: Aluminum.

Finish: Powder coated

Suspension: Steel cables.

Power cable: Silver braided.

Diffuser: Opal acrylic.

Drivers: HPF electronic drivers for 120-277V, 347V (EU-240V).

Integral Emergency system: Emergency option provides a 1.5 hour (3 hours for EU) emergency lighting facility. The self contained system includes the inverter module, NiCad batteries, LED charge indicator and test switch (NA only). Not available with a 347V supply.

BIOS: For circadian lighting, consult factory.

PoE: Can be integrated into your data network via Power over Ethernet (PoE) connectivity.

Mechanical: Luminaires mount directly over J box (by others).

Reported L70 @25°C (77°F): > 60,000 hrs @ 2000 lumens/ft (6000 lumens/m)

Estimated L70 @25°C (77°F): > 165,000 hrs @ 2000 lumens/ft (6000 lumens/m)

Delivered lumens: Delivered lumens & LPW based on 4000K CRI 80+

Approvals: Damp Location (Indoor use only).

Design: US Design Patent Pending.

Designed by: Serge Cornelissen.

## Features & tech specs

_Source: Configurator page (Tech Specs) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#specs_

### Body

Aluminum.

### Finish

Powder coated

### Suspension

Steel cables.

### Power cable

Silver braided.

### PoE

Can be integrated into your data network via Power over Ethernet (PoE) connectivity.

### BIOS

For circadian lighting, consult factory.

### Drivers

HPF electronic drivers for 120-277V, 347V (EU-240V). The driver is integral to the fixture housing.

### Lens

Opal acrylic. 2.4" width.

### Delivered lumens

Delivered lumens & LPW based on 4000K CRI 80+

### Mechanical

Luminaires mount directly over J box (by others).

### Reported L70 @25°C (77°F)

> 60,000 hrs @ 2000 lumens/ft (6000 lumens/m)

### Estimated L70 @25°C (77°F)

> 165,000 hrs @ 2000 lumens/ft (6000 lumens/m)

### Integral Emergency system 

Emergency option provides a 1.5 hour (3 hours for EU) emergency lighting facility. The self contained system includes the inverter module, NiCad batteries, LED charge indicator and test switch (NA only). Not available with a 347V supply.

### Luminaire Level Lighting Controls

This product can be configured for integration with luminaire-level lighting controls. Contact the factory for available options and project-specific requirements.

### Tunable White

Tunable White range from 2700K to 6500K is available; contact the factory for details.

### RGBW

RGBW available, consult factory.

### Approvals

Damp Rated.

### Designed by  

Serge Cornelissen.

### Design

US Pat. No. D959,043.

### Seismic Bracing

Seismic bracing kits are available to meet compliance requirements. Consult the factory for details.

### Sustainability

Designed for on-site LED board, driver, and optic replacement. Contact the factory for maintenance documentation.

## Approvals, mountings & applications

_Source: Configurator page (Tech Specs) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#specs_

- **Approvals / certifications:** ETL, CE, Grounding, Damp Location (Indoor Use), Mounting Suited On Flammable Surfaces, IP 20
- **Mountings:** Suspended Direct, Suspended Direct/Indirect
- **Industries / applications:** Bios, Declare, PoE
- **Optics & features icons:** Direct, Indirect UD1, Indirect UD3

## Images & media

_Source: Configurator page (gallery) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#gallery_

- Product image: https://betacalco.com/components/com_configbox/data/store/public/custom_media/bc_product_images/569-thumb-5800.png
- Gallery 1 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/2262-1920w-1630.jpg — OFFICE
- Gallery 2 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/2263-1920w-9120.jpg — GOLD LOUVER
- Gallery 3 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/2348-1920w-9200.jpg — BOARDROOM
- Gallery 4 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/4613-1920w-6900.jpg
- Gallery 5 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/4614-1920w-8390.jpg
- Gallery 6 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/2267-1920w-4560.jpg — BLACK LOUVER
- Gallery 7 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/2264-1920w-1230.jpg — FROSTED LOUVER
- Gallery 8 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/2265-1920w-8280.jpg — CHROME LOUVER
- Gallery 9 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/2266-1920w-7520.jpg — CHAMPAGNE LOUVER
- Gallery 10 (image): https://betacalco.com/components/com_configbox/data/store/public/custom_media/gallery_images/2365-1920w-1600.jpg — UPLIGHT (TOP VIEW)

## Downloads & documents

_Source: Configurator page (downloads) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#downloads_ · _Source: Resources & Downloads page — https://betacalco.com/resources_

| Type | Title | URL | Notes |
|---|---|---|---|
| Full Specsheet | Full Specification Sheet | imperial https://betacalco.com/specsheets/lelouvre-systems-pd/full/imperial · metric https://betacalco.com/specsheets/lelouvre-systems-pd/full/metric |  |
| Regular files | IES Files | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4705 | files: LE LOUVRE SYSTEMS PD IES FILES.zip |
| Regular files | LDT Files | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4706 | files: LE LOUVRE PD SYSTEMS LDT FILES.zip |
| BIM files | BIM Files | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4863 |  |
| Regular files | Bios | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4668 | files: BetaCalco-BIOS (1).pdf |
| Regular files | PoE | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4665 | files: POE (3).pdf |
| Dimensional Diagrams | Dimensional diagrams | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4766 |  |
| Installation Guides | Installation Instructions | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4779 | login required |
| Regular files | Aircraft Cable Instructions | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4667 | login required; files: Aircraft Cable Instructions Grid Ceiling (G1)- 01-27-2022.pdf, Aircraft Cable Instructions Hard Ceiling (H1)- 01-27-2022.pdf |
| Product Images | Product Images | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4805 | A zip of the gallery images at 1920px. |
| Global File | Declare | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=5015 |  |
| Performance Data | Performance Data | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=6854 |  |
| Global File | Linear Length Configurations | https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=7113 |  |

## Dimensional diagrams

_Source: Full specification sheet (PDF, imperial) — https://betacalco.com/specsheets/lelouvre-systems-pd/full/imperial_ · _Source: Configurator page (downloads) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#downloads_

The drawings with the fixture's dimensions, as printed in the specification sheet. Dimension values in text form (length, diameter, depth, weight) are on the answers of the configurator questions that carry them, under "attributes". The dimensions are drawn in the images; they are not extracted as data here.

- Dimensional diagrams (PDF): https://betacalco.com/index.php?option=com_configbox&controller=bcproductmaterials&task=getMaterial&materialId=4766
- 1: https://betacalco.com/components/com_configbox/data/store/public/custom_media/diagrams/1328-slide_2x-3160.png

## Photometric & performance data

_Source: Full specification sheet (PDF, imperial) — https://betacalco.com/specsheets/lelouvre-systems-pd/full/imperial_ · _Source: Configurator page (live figures under the configurator) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#configurator_

- Live performance figures shown on the configurator page: no

### Direct Frosted Louver with Comfort Lens (DD4) Data based on CCT: 4000K, CRI 80+, UGR

| Lumen/Ft | Watt/Ft | LPW |
|---|---|---|
| 1200 | 13 | 101 |
| 1000 | 9 | 107 |
| 800 | 7 | 109 |
| 700 | 6 | 111 |
| 600 | 5 | 115 |
| 500 | 4 | 115 |
| 400 | 3 | 115 |
| 300 | 3 | 116 |
| 200 | 2 | 121 |

### Direct Black Louver with Comfort Lens (DD4) Data based on CCT: 4000K, CRI 80+, UGR

| Lumen/Ft | Watt/Ft | LPW |
|---|---|---|
| 500 | 13 | 40 |
| 400 | 9 | 42 |
| 300 | 7 | 43 |
| 200 | 5 | 45 |
| 100 | 2 | 47 |

### Direct Satin Chrome Louver with Comfort Lens (DD4) Data based on CCT: 4000K, CRI 80+, UGR

| Lumen/Ft | Watt/Ft | LPW |
|---|---|---|
| 800 | 13 | 60 |
| 700 | 11 | 60 |
| 600 | 9 | 63 |
| 500 | 7 | 65 |
| 400 | 5 | 68 |
| 300 | 3 | 68 |
| 200 | 3 | 68 |
| 100 | 2 | 69 |

### Direct Satin Gold Louver with Comfort Lens (DD4) Data based on CCT: 4000K, CRI 80+, UGR

| Lumen/Ft | Watt/Ft | LPW |
|---|---|---|
| 800 | 13 | 59 |
| 700 | 11 | 59 |
| 600 | 9 | 62 |
| 500 | 7 | 63 |
| 400 | 5 | 66 |
| 300 | 3 | 66 |
| 200 | 3 | 66 |
| 100 | 2 | 68 |

### Direct Satin Champagne Louver with Comfort Lens (DD4) Data based on CCT: 4000K, CRI 80+, UGR

| Lumen/Ft | Watt/Ft | LPW |
|---|---|---|
| 800 | 13 | 60 |
| 700 | 11 | 60 |
| 600 | 9 | 63 |
| 500 | 7 | 65 |
| 400 | 5 | 68 |
| 300 | 3 | 68 |
| 200 | 3 | 68 |
| 100 | 2 | 69 |

### Indirect Batwing (UD1) Data based on CCT: 4000K, CRI 80+

| Lumen/Ft | Watt/Ft | LPW |
|---|---|---|
| 1600 | 13 | 129 |
| 1200 | 9 | 137 |
| 1000 | 7 | 140 |
| 750 | 5 | 146 |
| 500 | 3 | 147 |
| 250 | 2 | 152 |

### Indirect Asymmetric (UD3) Data based on CCT: 4000K, CRI 80+

| Lumen/Ft | Watt/Ft | LPW |
|---|---|---|
| 1200 | 13 | 97 |
| 1000 | 10 | 100 |
| 750 | 8 | 103 |
| 500 | 5 | 107 |
| 250 | 2 | 112 |

### TM-30: CCT 2700K

Graphic: https://betacalco.com/components/com_configbox/data/store/public/custom_media/tm30/10-9810.jpg

| Values |  |
|---|---|
| CRI(Ra) | 93 |
| CRI(R9) | 61 |
| TM30(Rf) | 91 |
| TM30(Rg) | 98 |
| Duv | -0.0022 |

### TM-30: CCT 3000K

Graphic: https://betacalco.com/components/com_configbox/data/store/public/custom_media/tm30/11-7840.jpg

| Values |  |
|---|---|
| CRI(Ra) | 92 |
| CRI(R9) | 58 |
| TM30(Rf) | 92 |
| TM30(Rg) | 100 |
| Duv | -0.0003 |

### TM-30: CCT 3500K

Graphic: https://betacalco.com/components/com_configbox/data/store/public/custom_media/tm30/12-4750.jpg

| Values |  |
|---|---|
| CRI(Ra) | 91 |
| CRI(R9) | 53 |
| TM30(Rf) | 90 |
| TM30(Rg) | 99 |
| Duv | -0.0007 |

### TM-30: CCT 4000K

Graphic: https://betacalco.com/components/com_configbox/data/store/public/custom_media/tm30/13-2380.jpg

| Values |  |
|---|---|
| CRI(Ra) | 93 |
| CRI(R9) | 64 |
| TM30(Rf) | 90 |
| TM30(Rg) | 98 |
| Duv | 0.0000 |

## How the configuration code is built

_Source: Configurator page (the configurator) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#configurator_

The configuration code is the answer codes of the questions below, in this order, joined by "/". A question that is not answered contributes its default code when it has one, otherwise nothing. Answers marked "(none)" contribute nothing. Questions that create sub-positions (accessories quoted as their own line) are not part of the code.

| # | Question | Default code | Luminaire code |
|---|---|---|---|
| 1 | Straight Section 2ft (id 5194) |  | yes |
| 2 | Straight Section 4ft (id 5051) |  | yes |
| 3 | Straight Section 6ft (id 5052) |  | yes |
| 4 | Straight Section 8ft (id 5053) |  | yes |
| 5 | Straight Section 10ft (id 5054) |  | yes |
| 6 | Straight Section 12ft (id 5055) |  | yes |
| 7 | Corner Section (28"x28" L shape) (id 5056) |  | yes |
| 8 | Louver (id 4907) |  |  |
| 9 | Lm/ft (Direct) (id 4908) |  |  |
| 10 | Lm/ft (Indirect) (id 4909) |  |  |
| 11 | CRI (id 4910) |  |  |
| 12 | CCT (Direct) (id 4911) |  |  |
| 13 | CCT (Indirect) (id 4912) |  |  |
| 14 | Direct Lens (id 4913) |  |  |
| 15 | Indirect Lens (id 4914) |  |  |
| 16 | Blackout Plate (id 4915) |  |  |
| 17 | Voltage (id 4916) |  |  |
| 18 | Dimming (id 4917) |  |  |
| 19 | Ceiling Type (id 4918) |  |  |
| 20 | Suspension (id 4919) |  |  |
| 21 | Fixture Finish (id 4920) |  |  |
| 22 | Canopy Finish (id 4921) |  |  |
| 23 | Emergency (id 4922) |  |  |
| 24 | Circuits (id 4923) |  |  |
| 25 | Sensors (id 5420) |  |  |

## Configurator: questions and answers

_Source: Configurator page (the configurator) — https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#configurator_ · _Source: Full specification sheet (PDF, imperial) — https://betacalco.com/specsheets/lelouvre-systems-pd/full/imperial_

Questions are listed in the order they appear. Answer codes are the code segments that make up the configuration code. IDs are the identifiers the configurator uses (question id = element id, answer id = option-assignment id).

Some questions and answers are only available in certain combinations of other answers. Those availability rules are not listed here; the JSON document carries them per question and per answer (`visible_when` as a sentence, `visible_when_rule` as the raw rule).

1 page(s), 25 question(s), 138 answer(s).

#### Straight Section 2ft (question id 5194, type radiobuttons)

- Heading by unit system: metric "Straight Section 620mm", imperial "Straight Section 2ft"
- Heading shown on the page: Choose a Module
- Heading note: Make a selection from one of the following 7 sections. One power cord for every 50 linear feet. Connection parts for each section are shipped separately for on site assembly. Project drawings are not required for this product.
- Description: Available as Direct only.
- This question's answer codes are the luminaire codes (the product identifier part of the configuration code).

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 26197 | LE1PSL02 | 2ft middle section Direct [metric: 610mm middle section Direct; imperial: 2ft middle section Direct] |  |
| 26198 | LE1PSM02 | 2ft middle section with power cord Direct [metric: 610mm middle section with power cord Direct; imperial: 2ft middle section with power cord Direct] |  |
| 26199 | LE1PSN02 | 2ft section with end cap Direct [metric: 610mm section with end cap Direct; imperial: 2ft section with end cap Direct] |  |
| 26200 | LE1PSP02 | 2ft section with end cap and power cord Direct [metric: 610mm section with end cap and power cord Direct; imperial: 2ft section with end cap and power cord Direct] |  |

#### Straight Section 4ft (question id 5051, type radiobuttons)

- Heading by unit system: metric "Straight Section 1219mm", imperial "Straight Section 4ft"
- This question's answer codes are the luminaire codes (the product identifier part of the configuration code).

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 25168 | LE1PSL04 | 4ft middle section Direct [metric: 1219mm middle section Direct; imperial: 4ft middle section Direct] | Adds 4 to the fixture length. |
| 25169 | LE1PSM04 | 4ft middle section with power cord Direct [metric: 1219mm middle section with power cord Direct; imperial: 4ft middle section with power cord Direct] | Adds 4 to the fixture length. |
| 25171 | LE1PSN04 | 4ft section with end cap Direct [metric: 1219mm section with end cap Direct; imperial: 4ft section with end cap Direct] | Adds 4 to the fixture length. |
| 25172 | LE1PSP04 | 4ft section with end cap and power cord Direct [metric: 1219mm section with end cap and power cord Direct; imperial: 4ft section with end cap and power cord Direct] | Adds 4 to the fixture length. |
| 25173 | LE2PSL04 | 4ft middle section Direct/Indirect [metric: 1219mm middle section Direct/Indirect; imperial: 4ft middle section Direct/Indirect] | Adds 4 to the fixture length. |
| 25174 | LE2PSM04 | 4ft middle section with power cord Direct/Indirect [metric: 1219mm middle section with power cord Direct/Indirect; imperial: 4ft middle section with power cord Direct/Indirect] | Adds 4 to the fixture length. |
| 25175 | LE2PSN04 | 4ft section with end cap Direct/Indirect [metric: 1219mm section with end cap Direct/Indirect; imperial: 4ft section with end cap Direct/Indirect] | Adds 4 to the fixture length. |
| 25176 | LE2PSP04 | 4ft section with end cap and power cord Direct/Indirect [metric: 1219mm section with end cap and power cord Direct/Indirect; imperial: 4ft section with end cap and power cord Direct/Indirect] | Adds 4 to the fixture length. |

#### Straight Section 6ft (question id 5052, type radiobuttons)

- Heading by unit system: metric "Straight Section 1829mm", imperial "Straight Section 6ft"
- This question's answer codes are the luminaire codes (the product identifier part of the configuration code).

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 25177 | LE1PSL06 | 6ft middle section Direct [metric: 1829mm middle section Direct; imperial: 6ft middle section Direct] | Adds 6 to the fixture length. |
| 25178 | LE1PSM06 | 6ft middle section with power cord Direct [metric: 1829mm middle section with power cord Direct; imperial: 6ft middle section with power cord Direct] | Adds 6 to the fixture length. |
| 25179 | LE1PSN06 | 6ft section with end cap Direct [metric: 1829mm section with end cap Direct; imperial: 6ft section with end cap Direct] | Adds 6 to the fixture length. |
| 25180 | LE1PSP06 | 6ft section with end cap and power cord Direct [metric: 1829mm section with end cap and power cord Direct; imperial: 6ft section with end cap and power cord Direct] | Adds 6 to the fixture length. |
| 25181 | LE2PSL06 | 6ft middle section Direct/Indirect [metric: 1829mm middle section Direct/Indirect; imperial: 6ft middle section Direct/Indirect] | Adds 6 to the fixture length. |
| 25182 | LE2PSM06 | 6ft middle section with power cord Direct/Indirect [metric: 1829mm middle section with power cord Direct/Indirect; imperial: 6ft middle section with power cord Direct/Indirect] | Adds 6 to the fixture length. |
| 25183 | LE2PSN06 | 6ft section with end cap Direct/Indirect [metric: 1829mm section with end cap Direct/Indirect; imperial: 6ft section with end cap Direct/Indirect] | Adds 6 to the fixture length. |
| 25184 | LE2PSP06 | 6ft section with end cap and power cord Direct/Indirect [metric: 1829mm section with end cap and power cord Direct/Indirect; imperial: 6ft section with end cap and power cord Direct/Indirect] | Adds 6 to the fixture length. |

#### Straight Section 8ft (question id 5053, type radiobuttons)

- Heading by unit system: metric "Straight Section 2438mm", imperial "Straight Section 8ft"
- This question's answer codes are the luminaire codes (the product identifier part of the configuration code).

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 25185 | LE1PSL08 | 8ft middle section Direct [metric: 2438mm middle section Direct; imperial: 8ft middle section Direct] | Adds 8 to the fixture length. |
| 25186 | LE1PSM08 | 8ft middle section with power cord Direct [metric: 2438mm middle section with power cord Direct; imperial: 8ft middle section with power cord Direct] | Adds 8 to the fixture length. |
| 25187 | LE1PSN08 | 8ft section with end cap Direct [metric: 2438mm section with end cap Direct; imperial: 8ft section with end cap Direct] | Adds 8 to the fixture length. |
| 25188 | LE1PSP08 | 8ft section with end cap and power cord Direct [metric: 2438mm section with end cap and power cord Direct; imperial: 8ft section with end cap and power cord Direct] | Adds 8 to the fixture length. |
| 25189 | LE2PSL08 | 8ft middle section Direct/Indirect [metric: 2438mm middle section Direct/Indirect; imperial: 8ft middle section Direct/Indirect] | Adds 8 to the fixture length. |
| 25190 | LE2PSM08 | 8ft middle section with power cord Direct/Indirect [metric: 2438mm middle section with power cord Direct/Indirect; imperial: 8ft middle section with power cord Direct/Indirect] | Adds 8 to the fixture length. |
| 25191 | LE2PSN08 | 8ft section with end cap Direct/Indirect [metric: 2438mm section with end cap Direct/Indirect; imperial: 8ft section with end cap Direct/Indirect] | Adds 8 to the fixture length. |
| 25192 | LE2PSP08 | 8ft section with end cap and power cord Direct/Indirect [metric: 2438mm section with end cap and power cord Direct/Indirect; imperial: 8ft section with end cap and power cord Direct/Indirect] | Adds 8 to the fixture length. |

#### Straight Section 10ft (question id 5054, type radiobuttons)

- Heading by unit system: metric "Straight Section 3048mm", imperial "Straight Section 10ft"
- This question's answer codes are the luminaire codes (the product identifier part of the configuration code).

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 25193 | LE1PSL10 | 10ft middle section Direct [metric: 3048mm middle section Direct; imperial: 10ft middle section Direct] | Adds 10 to the fixture length. |
| 25194 | LE1PSM10 | 10ft middle section with power cord Direct [metric: 3048mm middle section with power cord Direct; imperial: 10ft middle section with power cord Direct] | Adds 10 to the fixture length. |
| 25195 | LE1PSN10 | 10ft section with end cap Direct [metric: 3048mm section with end cap Direct; imperial: 10ft section with end cap Direct] | Adds 10 to the fixture length. |
| 25196 | LE1PSP10 | 10ft section with end cap and power cord Direct [metric: 3048mm section with end cap and power cord Direct; imperial: 10ft section with end cap and power cord Direct] | Adds 10 to the fixture length. |
| 25197 | LE2PSL10 | 10ft middle section Direct/Indirect [metric: 3048mm middle section Direct/Indirect; imperial: 10ft middle section Direct/Indirect] | Adds 10 to the fixture length. |
| 25198 | LE2PSM10 | 10ft middle section with power cord Direct/Indirect [metric: 3048mm middle section with power cord Direct/Indirect; imperial: 10ft middle section with power cord Direct/Indirect] | Adds 10 to the fixture length. |
| 25199 | LE2PSN10 | 10ft section with end cap Direct/Indirect [metric: 3048mm section with end cap Direct/Indirect; imperial: 10ft section with end cap Direct/Indirect] | Adds 10 to the fixture length. |
| 25200 | LE2PSP10 | 10ft section with end cap and power cord Direct/Indirect [metric: 3048mm section with end cap and power cord Direct/Indirect; imperial: 10ft section with end cap and power cord Direct/Indirect] | Adds 10 to the fixture length. |

#### Straight Section 12ft (question id 5055, type radiobuttons)

- Heading by unit system: metric "Straight Section 3658mm", imperial "Straight Section 12ft"
- This question's answer codes are the luminaire codes (the product identifier part of the configuration code).

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 25202 | LE1PSL12 | 12ft middle section Direct [metric: 3658mm middle section Direct; imperial: 12ft middle section Direct] | Adds 12 to the fixture length. |
| 25204 | LE1PSM12 | 12ft middle section with power cord Direct [metric: 3658mm middle section with power cord Direct; imperial: 12ft middle section with power cord Direct] | Adds 12 to the fixture length. |
| 25205 | LE1PSN12 | 12ft section with end cap Direct [metric: 3658mm section with end cap Direct; imperial: 12ft section with end cap Direct] | Adds 12 to the fixture length. |
| 25207 | LE1PSP12 | 12ft section with end cap and power cord Direct [metric: 3658mm section with end cap and power cord Direct; imperial: 12ft section with end cap and power cord Direct] | Adds 12 to the fixture length. |
| 25208 | LE2PSL12 | 12ft middle section Direct/Indirect [metric: 3658mm middle section Direct/Indirect; imperial: 12ft middle section Direct/Indirect] | Adds 12 to the fixture length. |
| 25209 | LE2PSM12 | 12ft middle section with power cord Direct/Indirect [metric: 3658mm middle section with power cord Direct/Indirect; imperial: 12ft middle section with power cord Direct/Indirect] | Adds 12 to the fixture length. |
| 25210 | LE2PSN12 | 12ft section with end cap Direct/Indirect [metric: 3658mm section with end cap Direct/Indirect; imperial: 12ft section with end cap Direct/Indirect] | Adds 12 to the fixture length. |
| 25213 | LE2PSP12 | 12ft section with end cap and power cord Direct/Indirect [metric: 3658mm section with end cap and power cord Direct/Indirect; imperial: 12ft section with end cap and power cord Direct/Indirect] | Adds 12 to the fixture length. |

#### Corner Section (28"x28" L shape) (question id 5056, type radiobuttons)

- Heading by unit system: metric "Corner Section (711mmx711mm L shape)", imperial "Corner Section (28"x28" L shape)"
- This question's answer codes are the luminaire codes (the product identifier part of the configuration code).

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 25217 | LE1PSL01 | Corner with no end caps Direct |  |
| 25218 | LE1PSM01 | Corner middle with power cord Direct |  |
| 25219 | LE1PSN01 | Corner with Left end cap Direct |  |
| 25220 | LE1PSN03 | Corner with Right end cap Direct |  |
| 25221 | LE1PSP01 | Corner with Left end cap and power cord Direct |  |
| 25222 | LE1PSP03 | Corner with Right end cap and power cord Direct |  |
| 25223 | LE2PSL01 | Corner with no end caps Direct/Indirect |  |
| 25224 | LE2PSM01 | Corner middle with power cord Direct/Indirect |  |
| 25225 | LE2PSN01 | Corner with Left end cap Direct/Indirect |  |
| 25226 | LE2PSN03 | Corner with Right end cap Direct/Indirect |  |
| 25227 | LE2PSP01 | Corner with Left end cap and power cord Direct/Indirect |  |
| 25228 | LE2PSP03 | Corner with Right end cap and power cord Direct/Indirect |  |

#### Louver (question id 4907, type images, required)

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24310 | LV1 | Frosted | Finish: Louver - Frosted |
| 24311 | LV2 | Black | Finish: Louver - Black |
| 24312 | LV4 | Satin Chrome | Finish: Louver - Satin Chrome |
| 24313 | LV6 | Satin Gold | Finish: Louver - Satin Gold |
| 24314 | LV9 | Satin Champagne | Finish: Louver - Satin Champagne |

#### Lm/ft (Direct) (question id 4908, type radiobuttons, required)

- Heading by unit system: metric "Lm/m (Direct)", imperial "Lm/ft (Direct)"
- Description: All data shown based on DD3 diffuser.
- Spec sheet note: Lumens/ft are determined by the color of the Louver. Consult website for available lumens/ft based on selected louver. All data shown based on DD3 diffuser.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24324 | LPF010 | 100 lm/ft [metric: 330 lm/m; imperial: 100 lm/ft] |  |
| 24315 | LPF020 | 200 lm/ft [metric: 700 lm/m; imperial: 200 lm/ft] |  |
| 24320 | LPF030 | 300 lm/ft [metric: 1000 lm/m; imperial: 300 lm/ft] |  |
| 24316 | LPF040 | 400 lm/ft [metric: 1300 lm/m; imperial: 400 lm/ft] |  |
| 24321 | LPF050 | 500 lm/ft [metric: 1650 lm/m; imperial: 500 lm/ft] |  |
| 24317 | LPF060 | 600 lm/ft [metric: 2000 lm/m; imperial: 600 lm/ft] |  |
| 24323 | LPF070 | 700 lm/ft [metric: 2300 lm/m; imperial: 700 lm/ft] |  |
| 24318 | LPF080 | 800 lm/ft [metric: 2700 lm/m; imperial: 800 lm/ft] |  |
| 24319 | LPF100 | 1000 lm/ft [metric: 3300 lm/m; imperial: 1000 lm/ft] |  |
| 24322 | LPF120 | 1200 lm/ft [metric: 4000 lm/m; imperial: 1200 lm/ft] |  |

#### Lm/ft (Indirect) (question id 4909, type radiobuttons, required)

- Heading by unit system: metric "Lm/m (Indirect)", imperial "Lm/ft (Indirect)"
- Description: All data shown based on DD3 diffuser.
- Spec sheet note: Consult website for available lumens/ft based on selected louver.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24325 | LPG000 | Not required |  |
| 24327 | LPG025 | 250 lm/ft [metric: 800 lm/m; imperial: 250 lm/ft] |  |
| 24328 | LPG050 | 500 lm/ft [metric: 1650 lm/m; imperial: 500 lm/ft] |  |
| 24329 | LPG075 | 750 lm/ft [metric: 2450 lm/m; imperial: 750 lm/ft] |  |
| 24326 | LPG100 | 1000 lm/ft [metric: 3300 lm/m; imperial: 1000 lm/ft] |  |
| 24330 | LPG120 | 1200 lm/ft [metric: 4000 lm/m; imperial: 1200 lm/ft] |  |
| 24331 | LPG160 | 1600 lm/ft [metric: 5300 lm/m; imperial: 1600 lm/ft] |  |

#### CRI (question id 4910, type radiobuttons, required)

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24332 | CR80 | CRI 80+ |  |
| 24333 | CR90 | CRI 90+ |  |

#### CCT (Direct) (question id 4911, type radiobuttons, required)

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24334 | CTA30 | 3000K |  |
| 24335 | CTA35 | 3500K |  |
| 24336 | CTA40 | 4000K |  |

#### CCT (Indirect) (question id 4912, type radiobuttons, required)

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24337 | CTB00 | Not required |  |
| 24338 | CTB30 | 3000K |  |
| 24339 | CTB35 | 3500K |  |
| 24340 | CTB40 | 4000K |  |

#### Direct Lens (question id 4913, type radiobuttons, required)

- Description: ¹ Recommended for use with Frosted louver only. When standing at the end view of the profile on the side where the power cord is installed, the asymmetric beam will aim to the right.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24341 | DD1 | Asymmetric ¹ |  |
| 24343 | DD4 | Comfort |  |

#### Indirect Lens (question id 4914, type radiobuttons, required)

- Description (metric): ¹ Available up to 4000 lm/m.
- Description (imperial): ¹ Available up to 1200 lm/ft.
- Note: ¹ Available up to 1200 lm/ft.
- Spec sheet note: ¹ Available up to 1200 lm/ft.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24344 | UD0 | Not required |  |
| 24345 | UD1 | Batwing |  |
| 27233 | UD3 | Asymmetric diffuser ¹ |  |
| 39283 | UD4 | Extra Wide Batwing |  |

#### Blackout Plate (question id 4915, type radiobuttons, required)

- Description: ¹ Available on a per foot basis. May be required to prevent lighting up duct work in a loft type application.
- Description (metric): ¹ Available on a per 304.8mm basis. May be required to prevent lighting up duct work in a loft type application.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24346 | UB00 | Not required |  |
| 24347 | UB | Blackout plate ¹ | Takes a quantity: metric 1–50 qty (increments of 1); imperial 1–50 (increments of 1); the number is appended to the code. |

#### Voltage (question id 4916, type radiobuttons, required)

- Description: ¹ Not available in North America. ² Only available with DA01 dimming. ³ Only available with DA45 dimming.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24348 | V1 | 120/277V |  |
| 24349 | V2 | 240V ¹ |  |
| 24350 | V3 | 347V ² |  |
| 24351 | V4 | Low Voltage ³ |  |

#### Dimming (question id 4917, type radiobuttons, required)

- Description: ¹ Not available with 347V. ² Not available in North America. ³ Only available with V4.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24352 | DA01 | 0-10V Dimming 1.0% |  |
| 24353 | DA02 | 0-10V Dimming 0.1% ¹ |  |
| 24354 | DA20 | DALI Dimming 0.1% ¹ |  |
| 24355 | DA21 | DALI Dimming 1.0% ¹ |  |
| 24356 | DA30 | DSI/switchDim ² |  |
| 24357 | DA45 | PoE ³ |  |

#### Ceiling Type (question id 4918, type radiobuttons, required)

- Description: The cost for the canopies, power cables, connections mechanisms and endcaps for the fixture has been added to these items. ¹ Combo kit provided includes installation to T-bar and through tile mount. ² Designed for drywall ceilings.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24359 | G1 | Grid ceiling ¹ |  |
| 24358 | H1 | Hard ceiling ² |  |

#### Suspension (question id 4919, type radiobuttons, required)

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24360 | HLA03 | 3ft cable suspension [metric: 914mm cable suspension; imperial: 3ft cable suspension] |  |
| 24361 | HLA06 | 6ft cable suspension [metric: 1829mm cable suspension; imperial: 6ft cable suspension] |  |
| 24362 | HLA09 | 9ft cable suspension [metric: 2.74m cable suspension; imperial: 9ft cable suspension] |  |

#### Fixture Finish (question id 4920, type images, required)

- Description: ¹ Wood grain finishes may incur longer lead times and setup charges. Consult factory for details.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24363 | FA01 | White - Textured | Finish: White - Textured |
| 24369 | FA02 | Black Metallic - Textured | Finish: Black Metallic Textured |
| 24364 | FA20 | Silver Metallic - Textured | Finish: Silver Metallic Textured |
| 24365 | FA25 | Gold Metallic - Textured | Finish: Gold Metallic Textured |
| 24371 | FA27 | Wood grain - Light Cherry ¹ | Finish: Wood Grain - Light Cherry |
| 24372 | FA28 | Wood grain - Dark Walnut ¹ | Finish: Wood Grain - Dark Walnut |
| 36061 | FA30 | Wood grain - White Oak ¹ | Finish: Wood Grain - White Oak |
| 24366 | FA44 | Midnight Blue Metallic - Textured | Finish: Midnight Blue Metallic Textured |
| 24373 | FA45 | Copper Metallic | Finish: Copper Metallic |
| 24367 | FA46 | Charcoal Metallic - Textured | Finish: Charcoal Metallic Textured |
| 24368 | FA47 | Bronze Metallic - Textured | Finish: Bronze Metallic Textured |
| 24374 | FA52 | Champagne Metallic | Finish: Champagne Metallic |
| 24370 | FA53 | Red Metallic - Textured | Finish: Red Metallic Textured |

#### Canopy Finish (question id 4921, type images, required)

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24375 | CF01 | White | Finish: White - Textured |
| 24381 | CF02 | Black Metallic - Textured | Finish: Black Metallic Textured |
| 24376 | CF20 | Silver Metallic - Textured | Finish: Silver Metallic Textured |
| 24377 | CF25 | Gold Metallic - Textured | Finish: Gold Metallic Textured |
| 24378 | CF44 | Midnight Blue Metallic - Textured | Finish: Midnight Blue Metallic Textured |
| 24383 | CF45 | Copper Metallic | Finish: Copper Metallic |
| 24379 | CF46 | Charcoal Metallic - Textured | Finish: Charcoal Metallic Textured |
| 24380 | CF47 | Bronze Metallic - Textured | Finish: Bronze Metallic Textured |
| 24384 | CF52 | Champagne Metallic | Finish: Champagne Metallic |
| 24382 | CF53 | Red Metallic - Textured | Finish: Red Metallic Textured |

#### Emergency (question id 4922, type radiobuttons, required)

- Description: ¹ A drawing will be required at time of ordering to determine the required number and location of the emergency sections or generator circuits. Not available in 347V.
- Spec sheet note: ¹ A drawing will be required at time of ordering to determine the required number and location of the emergency sections or generator circuits. Available upon request, consult factory for details. Not available with 347V.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24386 | E0 | Not required |  |
| 24385 | E1 | Emergency system - Integral ¹ | Available upon request, consult factory for details. |
| 24387 | E3 | Emergency generator circuit ¹ | Available upon request, consult factory for details. |

#### Circuits (question id 4923, type radiobuttons, required)

- Description: ¹ Independent control of uplight for LELP2P.

| Answer id | Code | Answer | Details |
|---|---|---|---|
| 24388 | CS1 | Single circuit |  |
| 24389 | CS2 | Dual circuit ¹ |  |

#### Sensors (question id 5420, type headingonly)

- Description: This product can be configured for integration with luminaire-level lighting controls. Contact the factory for available options and project-specific requirements.

## Codes, names and tags

_Source: Products page (search & filters) — https://betacalco.com/component/configbox/productlisting?listing_id=0_

- Luminaire codes: LE1PSL01, LE1PSL02, LE1PSL04, LE1PSL06, LE1PSL08, LE1PSL10, LE1PSL12, LE1PSM01, LE1PSM02, LE1PSM04, LE1PSM06, LE1PSM08, LE1PSM10, LE1PSM12, LE1PSN01, LE1PSN02, LE1PSN03, LE1PSN04, LE1PSN06, LE1PSN08, LE1PSN10, LE1PSN12, LE1PSP01, LE1PSP02, LE1PSP03, LE1PSP04, LE1PSP06, LE1PSP08, LE1PSP10, LE1PSP12, LE2PSL01, LE2PSL04, LE2PSL06, LE2PSL08, LE2PSL10, LE2PSL12, LE2PSM01, LE2PSM04, LE2PSM06, LE2PSM08, LE2PSM10, LE2PSM12, LE2PSN01, LE2PSN03, LE2PSN04, LE2PSN06, LE2PSN08, LE2PSN10, LE2PSN12, LE2PSP01, LE2PSP03, LE2PSP04, LE2PSP06, LE2PSP08, LE2PSP10, LE2PSP12
- Category: Linear
- Aperture (inches): 2.1 - 3.0
- Aperture (millimetres): 51 - 75
- Mounting: Suspended
- Types: Linear Profiles
- Features: Indirect, Asymmetric, Batwing, BIOS, Color Accent, Dali, Declare, Louvered, PoE, Tunable White, Low UGR, Wood Finish
- Shapes: Linear

## Related products (same family)

_Source: Product family page — https://betacalco.com/component/configbox/?view=bcproductsbyfamily&family_id=83_

- Le Louvre™ Suspended Continuous (id 369): https://betacalco.com/component/configbox/lelouvre/configurator — knowledge: https://betacalco.com/cb-api/bcproductknowledge/markdown?productId=369
- Le Louvre™ Continuous Recessed (id 412): https://betacalco.com/component/configbox/lelouvre-rec/configurator — knowledge: https://betacalco.com/cb-api/bcproductknowledge/markdown?productId=412
- Le Louvre™ Ceiling (id 526): https://betacalco.com/component/configbox/lelouvre-ceiling/configurator — knowledge: https://betacalco.com/cb-api/bcproductknowledge/markdown?productId=526
- Le Louvre Quad™ Suspended (id 553): https://betacalco.com/component/configbox/le-louvre-quad-pd/configurator — knowledge: https://betacalco.com/cb-api/bcproductknowledge/markdown?productId=553
- (Archive) Le Louvre Quad™ DO NOT USE Continuous Recessed (id 554): https://betacalco.com/component/configbox/le-louvre-quad-recessed/configurator — knowledge: https://betacalco.com/cb-api/bcproductknowledge/markdown?productId=554
- Le Louvre™ Wall Continuous (id 611): https://betacalco.com/products/lelouvre-wl/configurator — knowledge: https://betacalco.com/cb-api/bcproductknowledge/markdown?productId=611

## Pricing & ERP notes

- Pricing type: linear. Prices are not part of this document: they depend on the visitor's customer group and are shown in the configurator and the quote tools to signed-in agents. "linear" pricing is per length of fixture, "regular" is per unit.
- ERP configuration (Infor CPQ): available (ruleset LE-LOUVRE). Whether the ERP (Infor CPQ) can resolve a bill of materials for configurations of this product.

## Sources

- Configurator page (page): https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator
- Configurator page (intro) (page): https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#top-part
- Configurator page (Tech Specs) (page): https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#specs
- Configurator page (gallery) (page): https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#gallery
- Configurator page (downloads) (page): https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#downloads
- Resources & Downloads page (page): https://betacalco.com/resources
- Full specification sheet (PDF, imperial) (pdf): https://betacalco.com/specsheets/lelouvre-systems-pd/full/imperial
- Configurator page (live figures under the configurator) (page): https://betacalco.com/component/configbox/lelouvre-systems-pd/configurator#configurator
- Products page (search & filters) (page): https://betacalco.com/component/configbox/productlisting?listing_id=0
- Product family page (page): https://betacalco.com/component/configbox/?view=bcproductsbyfamily&family_id=83